By Martyn Lenthall | Business Energy Solutions | Sources checked 20 November 2026
A gas meter usually measures volume, while your supplier charges for energy in kilowatt hours, or kWh. To check the calculation, subtract the previous reading from the latest reading, check whether the meter is metric or imperial, and use the calorific value and conversion factors shown on your bill. Do not treat one meter unit as one kWh.
For a typical metric calculation, multiply the cubic metres used by the bill’s calorific value and by the volume correction factor, then divide by 3.6. An imperial reading may first need converting from hundreds of cubic feet to cubic metres. Check the unit printed on the meter and the basis used on the bill before doing the arithmetic.
Why does my gas meter show different units from my bill?
The meter records a volume of gas passing through it. The energy contained in that volume depends on the gas supplied. A kilowatt hour describes energy, not volume, so the supplier converts the meter consumption before applying your price per kWh.
This explains why a reading difference of 100 on a metric gas meter does not mean you have used 100 kWh. It also explains why copying a fixed multiplier from an old bill can give a slightly different answer from the supplier’s current calculation.
First match the bill to the correct supply and physical meter. Check the property, billing dates and meter serial number. If a meter was exchanged during the period, ask for the closing reading from the old meter and opening reading from the new one. Do not subtract readings from two different meters as though they were a continuous register.
Step 1: work out the meter reading difference
Subtract the previous reading from the current reading for the same meter. For example, readings of 12,400 and 12,500 give a difference of 100 units. Those figures are an illustration, not a recommended reading to submit.
Check whether the bill uses actual, customer-provided or estimated readings. Accurate conversion of an estimated reading still produces an estimated consumption figure. If the starting readings are wrong, getting the multiplication right will not establish the correct bill.
Follow the supplier’s instructions for reading your meter. GOV.UK’s guidance explains that the red part-units on the illustrated gas meters are not included in the reading submitted to the supplier. Check your own meter display and its unit markings rather than assuming every screen is arranged the same way.
Step 2: check whether the meter is metric or imperial
A metric gas meter records cubic metres, commonly marked m³. For the usual calculation, the reading difference is already in cubic metres, so there is no cubic-feet conversion step.
An imperial gas meter records cubic feet, marked ft³. The reading used for billing is commonly in hundreds of cubic feet. GOV.UK gives a factor of 2.83 to convert 100 cubic feet to cubic metres. Where a volume is supplied in individual cubic feet instead, the corresponding factor is 0.0283. Applying the wrong one creates a large error.
Do not choose the factor just because a calculator labels a box gas units. Confirm what those units mean. If the meter marking and the bill disagree, ask the supplier to check the meter details and billing setup before accepting the calculation.
Step 3: use the calorific value on your bill
Calorific value measures the heat energy available from a volume of gas. It is normally expressed in megajoules per cubic metre, or MJ/m³. GOV.UK explains that the figure on the bill is an average for the gas supplied to the property.
Use the calorific value for the billing period you are checking. A worked example may use 39.5, but that does not make 39.5 the correct figure for your business. Do not replace the supplier’s stated value with an internet average and assume a difference proves overcharging.
Step 4: apply the correction factor and convert to kWh
GOV.UK’s standard calculation applies a volume correction factor of 1.02264 to account for temperature and pressure. Dividing the result by 3.6 converts megajoules to kilowatt hours. The bill should explain the factors used in its calculation.
For the standard metric example, the formula is: cubic metres used × calorific value × 1.02264 ÷ 3.6 = kWh. If your business has a different metering or volume-correction arrangement, ask the supplier to explain the actual billed basis rather than adding a correction twice.
For an imperial reading expressed in hundreds of cubic feet, the standard example becomes: meter units used × 2.83 × calorific value × 1.02264 ÷ 3.6 = kWh. Keep the units visible alongside your working so you can see where each factor belongs.
A metric gas conversion example
Suppose a metric meter records 100 m³ used and the bill gives a calorific value of 39.5 MJ/m³. Using the standard correction factor, the calculation is 100 × 39.5 × 1.02264 ÷ 3.6. This gives about 1,122.06 kWh.
That is a consumption example, not a price quote. Your own consumption, calorific value and bill rounding may differ. Keep enough decimal places during the calculation and compare the supplier’s stated rounding before treating a small difference as an error.
An imperial gas conversion example
Suppose the reading difference is 10 units, with each unit representing 100 cubic feet. First calculate 10 × 2.83 = 28.3 m³. With the same illustrative calorific value of 39.5 and standard correction factor, the result is 10 × 2.83 × 39.5 × 1.02264 ÷ 3.6, or about 317.54 kWh.
This example is deliberately different from 10 individual cubic feet. Check the bill’s description and the meter register before entering the figures. An imperial-to-metric mismatch deserves a supplier check, not a guess about which total looks more reasonable.
Why does the kWh total not equal the whole bill?
The kWh calculation establishes the energy consumption used in the relevant part of the bill. The supplier then applies the agreed unit price. Your total may also include a standing charge, VAT, Climate Change Levy where applicable, credits or adjustments, and other charges permitted by the contract.
A correct consumption conversion does not prove every other charge is correct. Equally, a high total does not by itself prove the conversion is wrong. Check the reading period, kWh, unit price and each separate charge against the contract and bill explanation.
What should I send the supplier if the calculation looks wrong?
Keep a copy of the bill, dated meter photographs where safe to take, the meter serial number and the reading dates. Set out the meter units, reading difference, calorific value and conversion factors you used. Explain the specific mismatch instead of sending only a different final total.
Ask the supplier to confirm the recorded meter type and how it calculated the billed kWh. If it cannot resolve the question, use its complaints process and keep the correspondence. Eligibility for further independent help depends on the business and complaint, so check the appropriate route rather than assuming all businesses have identical protections.
Can BES help me understand a business gas bill?
Business Energy Solutions is an introducer, not your energy supplier. BES can help you identify the information needed to discuss your business energy supply and compare quotes on a consistent basis. The supplier remains the first place to query its meter readings, conversion calculation or billing records. Do not replace a bill dispute with a supplier switch and assume the disputed balance has disappeared.
Our separate guides explain business gas quotes and the other reasons a business energy bill can be high. Keep this calculation check separate from the choice of supplier, contract length and future unit price.
Gas conversion questions for business bills
How many kWh are in one unit of gas?
There is no single answer until you know what one unit means. On a metric meter, one unit normally means one cubic metre. On imperial meters, the submitted reading commonly counts hundreds of cubic feet. The kWh equivalent then depends on the calorific value used for the period. Check the unit first, then the conversion formula.
Does a smart gas meter remove the need for conversion?
A digital display does not turn a volume measurement into a different physical quantity. Check which screen shows the meter reading and which unit it uses. If an online account or display also shows energy usage, do not submit a cost figure as a meter reading. Follow the meter and supplier’s instructions rather than assuming the largest number is the correct one.
Can I use an online gas bill calculator?
An online tool can help you check arithmetic, but it needs the right inputs. Choose the metric or imperial option that matches your meter readings. Check whether it assumes hundreds of cubic feet, which calorific value it uses and whether you can enter the factors from your actual bill. A gas bill calculator is not evidence that the underlying readings are correct.
Write the conversion formula beside the result and retain your inputs. Some tools label cubic metres as cubic meters; the spelling does not change the unit. The important distinction is m³ versus ft³ and whether an imperial figure represents individual or hundreds of cubic feet.
Can an estimated bill have a correct conversion but the wrong total?
Yes. Energy suppliers can calculate the conversion correctly from an estimated volume while the estimate itself differs from actual gas usage. Compare the reading dates and reading types with your records. Ask the gas supplier to explain the estimate and how an accepted actual reading will be reflected in the account.
Does a higher kWh figure mean my unit rate has increased?
No. Energy consumption and price are separate parts of gas bills. Higher gas usage can increase the consumption charge even if the unit rate is unchanged. A different unit rate can change the charge even if usage is the same. Check both, then account for standing charges and any other applicable items.
Use the calculation to understand your existing gas supply before making an energy price comparison. Converting the same volume accurately helps you compare like for like, but it does not by itself show whether a future contract is suitable. Energy prices, contract terms and the amount of energy your business uses remain separate questions.
Can I multiply every gas reading by the same number?
Not safely without checking the unit and factors. The metric example above gives roughly 11.22 kWh per cubic metre with its illustrative calorific value. Imperial meters need the extra volume conversion first. Energy suppliers may also use a different average calorific value for the next period, so an approximate shortcut should not replace the bill’s stated conversion formula.
A shortcut may help with a rough sense-check of gas consumption, but keep its assumptions visible. When checking a disputed charge, use the actual readings and factors for that period. Do not adjust the figures until they agree with the amount you expected to pay.
How do I compare energy consumption across two gas bills?
Compare the converted kWh and the number of days, rather than only the raw meter units or the amount paid. Dividing each period’s kWh by its days gives a simple daily average. That helps identify the effect of different billing periods, but it does not account for weather, opening hours or changes in the heating system and business activity.
If a meter changed from imperial to metric, a smaller reading difference does not by itself show energy savings. Convert each period on its own correct basis before comparing energy usage. A comparison of energy consumption is different from an energy-efficiency assessment, and neither changes the readings that should appear on the bill.
Source and related guides
GOV.UK, Office for Product Safety and Standards: Gas meter readings and bill calculation. https://www.gov.uk/guidance/gas-meter-readings-and-bill-calculation
BES: business gas. https://businessenergysolutions.co.uk/business-gas/
BES: how much business gas costs and why quotes differ. https://businessenergysolutions.co.uk/how-much-does-business-gas-cost-and-why-do-quotes-differ/
BES: why a business energy bill can be high. https://businessenergysolutions.co.uk/why-is-my-business-energy-bill-so-high/